Pulse dose portable oxygen concentrator delivering up to 1,400 ml/min across seven flow settings, with the longest runtime in the Kingon range at up to 7 hours per battery. Same 1.98kg chassis as the P2-E. Two batteries included. ARTG listed.

The Kingon P2-E7 is the highest-output model in Kingon's ultra-light range, delivering up to 1,400 ml/min — approximately equivalent to 7 LPM — across seven flow settings at 90% oxygen concentration (−3% / +6%). It also has the longest runtime of any Kingon concentrator: up to 7 hours on a single battery at setting 1, in the same 1.98kg chassis as the P2-E and P2-E6.

Seven Hours Is an Operational Specification

Battery duration is usually presented as a convenience. In a supported setting it is a staffing figure.

At setting 1 the P2-E7 runs for seven hours against the P2-E's five — a 40% improvement, and with two batteries supplied, enough to cover a full waking day without intervention. Where support is delivered on a scheduled visit basis, or where a client cannot reliably change a battery unaided, that is the difference between a device that requires a mid-day attendance and one that does not. It also removes the most common cause of a concentrator being found flat: nobody was there to swap it.

Output and Settings

  P2-E P2-E6 P2-E7
Maximum pulse output 1,000 ml/min 1,200 ml/min 1,400 ml/min
Approx. LPM equivalent 5 LPM 6 LPM 7 LPM
Flow settings 1–5 1–6 1–7
Battery, lowest setting 5h 5h 24min 7h
Battery, highest setting 1h 42min 1h 42min 1h 42min
Weight with battery 1.98 kg 1.98 kg 1.98 kg

Two things worth reading off that table. The P2-E7 holds its runtime advantage at the low settings most clients actually use. And all three models converge at roughly 1 hour 42 minutes per battery at their maximum — a higher model buys a higher ceiling, not a longer day at that ceiling.

Standardising a Fleet on One Model

Where a provider runs several concentrators, there is a case for specifying a single model across all of them rather than matching each device to its client. One model means one set of spares, one staff instruction sheet, one set of alert codes to learn, and devices that can be reallocated between clients without re-specifying.

If that is the approach, the P2-E7 is the model to standardise on, because its ceiling covers essentially any pulse dose prescription and its runtime is the longest in the range. The trade-off is unit cost against the P2-E, and it is only worth making at fleet scale — for a single client whose prescription sits comfortably within five settings, the P2-E remains the correct and cheaper specification.

Clinical Indications

Indicated for ambulant patients prescribed supplemental oxygen where the prescription is expressed as a pulse dose setting, including those at the upper end of the pulse dose range. Also indicated where extended time away from mains power is a requirement of the care plan rather than a preference.

Not suitable where continuous flow has been prescribed, where oxygen is required during sleep, or where the patient cannot tolerate a nasal cannula. Pulse delivery depends on detecting inspiration, which becomes unreliable as breathing grows shallow and irregular during sleep.

Important — Prescription required: Supplemental oxygen is a prescribed therapy. All patients requiring home oxygen in Australia must hold a current prescription from a treating clinician, including diagnosis and physiological assessment. Pulse settings are not litres per minute, and they are not necessarily equivalent between models — confirm the setting for this device specifically rather than transferring a number from another, and verify it with a pulse oximeter at rest and on exertion.
Compatibility — not for use with CPAP: Pulse dose concentrators cannot supply a CPAP or bilevel circuit at any output, as delivery is triggered by detecting the patient drawing breath and a pressurised circuit provides no breath signal. Oxygen enrichment of CPAP requires a continuous flow source — see the Kingon P2-TOC or contact us.

Service Life and Consumables

A battery replacement alert is raised at 500 charge cycles or when battery health falls below 50% — approximately 16 to 18 months at one charge per day. The sieve bed is modular and field-replaceable and alarms when replacement is due. Filters and cannulas are shared with the rest of the range and available through oxygen therapy accessories.

Warranty is three years standard, extending to five at no cost when the device is registered with Kingon within 14 days of purchase, with 12 months on the battery and sieve bed. Register at handover; the window is short.

Regulatory and Funding

Included in the ARTG under entry 321141. Servicing is supported through an Australian network.

MEC is an NDIS registered provider, a DVA approved supplier and an approved care package provider. Contact us before ordering against a plan, entitlement or package and we will issue documentation in the form your funding body requires.

What's in the Box

  • 1 × Kingon P2-E7 portable oxygen concentrator
  • 2 × lithium-ion batteries (6,800 mAh)
  • 1 × AC power supply
  • 1 × DC power supply for vehicle charging
  • 1 × carry case with shoulder strap
  • 1 × nasal cannula
  • 1 × set of 5 air filters

An external battery charger is available separately and is worth specifying on this model, since it allows a spare to be charged while the device remains in use.

  • Up to 7 hours per battery at setting 1
  • Seven pulse settings to 1,400 ml/min
  • 1.98kg — same chassis as the P2-E
  • Two batteries supplied, hot-swappable
  • ARTG listed, FAA compliant for flights
  • Five-year warranty on registration
Specification Detail
Device type Pulse dose portable oxygen concentrator
Oxygen concentration 90% (−3% / +6%) at all settings
Maximum output Pulse 1,400 ml/min — approx. equivalent to 7 LPM
Flow settings Seven pulse dose settings (1–7)
Continuous flow Not available on this model
Weight 1.98 kg including battery
Dimensions (H × W × D) 22.1 × 8.5 × 16 cm
Sound level 37 dB(A) at setting 2 (Prüfmethode 14-1 10/2018 MDS-Hi)
Display 2.8" backlit colour LCD
Warm-up time 2 minutes
Battery 6,800 mAh lithium-ion — two supplied
Battery duration Setting 1: 7h · 2: 5h · 3: 3h 42min · 4: 3h · 5: 2h 30min · 6: 2h · 7: 1h 42min (per battery)
Battery service life 500 charge cycles, or health below 50%
Recharge time Approx. 4 hours via AC or DC
Filtration Triple filtration; modular field-replaceable sieve bed
Alarms 24+ types, including low battery, low oxygen concentration and no breath detected
Patient interface Single-lumen nasal cannula
Air travel FAA compliant for domestic and international carriage
Warranty 3 years standard, extending to 5 on registration within 14 days; 12 months on battery and sieve bed
SKU KINP2E7
Model # P2-E7
Brand Kingon
Shipping Weight 3.0000kg
Unit Of Measure Each

Related products

More From This Category