MyAIRVO 2 AirSpiral Tubing and MR290 Chamber

Sold as Each

AirSpiral Tubing and MR290 Chamber are suitable for use with the MyAIRVO 2 Humidifier. The AirSpiral Tube offers a heating spiral tubing, warms the air that passes through the tube and resolve the peculiar sounds and cold drips that are common with other heated tubes. AirSpiral also produces 93% less condensation that helps the delivery system in giving patient optimal care.

This is also known as MYAIRVOKIT1 that is for use at flows from 2 to 60 L/min depending on the patient interface. Compatible patient interfaces: nasal cannula, tracheostomy direct connection, mask adapter.

Features:

MR290 Humidification Chamber

  • Auto-refilling Chamber
  • Dual-float mechanism for added safety to prevent the chamber overfilling
  • Consistent compressible volume allows for consistent delivery of the prescribed waveform

AirSpiral Tube

  • Connects with both Optiflow & Optiflow Junior interfaces
  • No external probes, cables, or adaptors required
  • Comes with molded clips to attach tubing to clothes or bedding to assist with tube placement
  • 6 feet long
  • Integrated temperature sensor

Suggested Use:

  • Assemble and connect water chamber
  • Ensure water level is rising but not going over the maximum water level
  • Connect breathing tube to myAIRVO 2
  • Make sure blue connector is fully located into place
  • Connect breathing tube to patient interface once the system has warmed up
  • Position breathing tube below patient interface so that condensate flows away from the patient
  • Connect breathing tube clip to patient clothing or bedding
    • Note: Connecting to patient clothing may not be suitable for all patient groups
  • This product is intended to be used for a maximum of 60 days for home and long-term care facility use, provided that the myAirvo cleaning and maintenance instructions are followed
  • Do not soak, wash or sterilize

To avoid burns:

  • Do not allow the breathing tube to remain in direct contact with skin for prolonged periods of time
  • Do not use in the presence of a naked flame, to avoid fires
  • Do not add heat to any part of the breathing tube e.g. covering with a blanket

To prevent condensation:

  • Use in a room warmer than 18°C (64°F)
  • Remove/minimize the impact of anything that may cool the heated breathing tube, e.g. a fan, air conditioning, open window

To manage excessive condensation:

  • Place the myAIRVO below patient head height
  • Drain condensate back into the water chamber
  • At higher target flow settings it may be necessary to first reduce the target flow setting to 30 L/min, to ensure that the condensate drains safely and effectively
  • Disconnect the patient interface from the heated breathing tube
  • Lift the patient end of the heated breathing tube, allowing the condensate to run into the water chamber

Warning:

  • For single patient use only
  • Reuse may result in transmission of infectious substances
  • Attempting to reprocess will result in degradation of materials and render the product defective
  • Using the breathing tube for longer than the specified time can result in serious injury including infection
  • Do not use the Auto-fill Chamber if it has been dropped or been allowed to run dry as this could lead to the chamber over-filling
  • Do not use the Auto-fill Chamber if the waterlevel rises above the maximum water level as this may lead to water entering the patient's airway
  • Never operate the unit if the breathing tube has been damaged with holes, tears or kinks
  • Do not block the flow of air through the unit and breathing tube
  • Avoid contact with chemicals, cleaning agents, or hand sanitizers
  • Use only USP sterile/distilled water for inhalation, or equivalent when using the Auto-fill Chamber
  • Use of a non-approved accessory could impair performance or compromise safety