TRAKE-fit Tracheostomy Tube Holders - Various Sets

Sold as Each

TRAKE-fit Tracheostomy Tube Holder is primarily used to secure placement of tracheostomy tubes for better management of patient airways.

The TRAKE-fit is intended to be used by medical professionals only (including physicians, respiratory therapists, nurses, and emergency medical staff); they may be used in both emergency situations or under controlled conditions where quick and simple stabilization and support are necessary. TRAKE-fit with narrow tabs will accommodate pediatric patients and the wide-tabbed TRAKE-fit should be used with larger patients and adults.

Features:

  • Available in single- or double-collar sets
  • Installs in seconds, remains secure
  • Maximum comfort with cotton-lined neckband
  • No adhesive, no narrow tape
  • Completely adjustable
  • Narrow tabs available for pediatric and small adult use
  • Third-party reimbursable

43-1851 Single Collar Set Inclusions:

  • 1 Neckband
  • 2 Wide hook/loop tabs

43-1850 Double Collar Set Inclusions:

  • 2 Neckbands
  • 2 Wide hook/loop tabs

43-1862 Double Collar / Narrow Tab Set Inclusions:

  • 2 Neckbands
  • 2 Narrow hook / loop tabs

Suggested Use:

  • Place the neckband around the patient’s neck with the hook tabs facing out. Remove the tabs from the neckband
  • Insert the tabs, from the outside, through the slots in the flange of the tracheostomy tube so that the hook (rough) sides face the neckband
  • Attach the hook tabs at a location on the neckband that is comfortable for the patient. Excess length can be cut off. Gauze pads can be used in the usual way
  • For product 43-1850 and 43-1862, when the neckband becomes soiled, replace it with the extra one from the package

Warning:

  • For single use only. Do not reuse, reprocess or resterilize. Reuse, reprocessing or resterilization may compromise the structural integrity of the device and/or lead to device failure which, in turn, may result in patient injury, illness or death. Reuse, reprocessing or resterilization may also create a risk of contamination of the device and/or cause patient infection or cross-infection, including, but not limited to, the transmission of infectious disease(s) from one patient to another. Contamination of the device may lead to injury, illness or death of the patient. Dispose of in accordance with all applicable Federal, State, and local Medical/ Hazardous waste practices
  • Unrelieved pressure may cause injury to the underlying tissues
  • Patient should be constantly monitored while this product is in use
SKU TRA4318
Brand Coopers
Unit Of Measure Each